Browsing Posts in Prodotti

Reading Time: 2 minutesIf you are planning to backup a Microsoft Hyper-V cluster with Veeam Backup & Replication you may have some issues during the configuration of your environment. Compared to VMware vSphere backup where are defined some Veeam proxy on Windows machines (virtual or physical), in a Hyper-V backup, each Hyper-V node act also as a Veeam proxy!

Reading Time: 3 minutesVMware la rilasciato (ancora il 15 febbraio) una nuova versione della vCSA version: vCenter Server 6.5 U1f, che porta il build number a 7801515. In questa nuova versione della vCSA viene aggiornato il Photon contro due delle vulnerabilità relative alle problematiche Meltdown e Spectre. La nuova patch vCenter Server 6.5 U1f risolve le problematiche bounds-check bypass(Spectre-1, CVE-2017-5753) e rogue data cache load (Meltdown, CVE-2017-5754). Per la vulnerabilità branch target injection (Spectre-2, CVE-2017-5715) non c’è invece ancora nessuna patch. VMware ha aggiornato il documento VMSA-2018-0007, ma non ancora il VMSA-2018-0004.2 che riporta come ultima versione del vCenter il 6.5 is still 6.5U1e!

Reading Time: 3 minutesRunecast announces the new release version 1.7 of its proactive issue detection software, Runecast Analyzer. After the Meltdown and Spectre detection added in the previous releases, this latest version brings other interesting news. Runecast Analyzer is powered by the largest database of automated VMware KB articles which feed its internal archive of known issues. The interesting aspect of this tool is that it’s very easy and fast to be deployed and that it can work fully in offline mode!

Reading Time: 2 minutesWhen you add a Veeam proxy to the Veeam Backup infrastructure, in some cases you can have an error message like this: “Failed to create persistent connection to ADMIN$” And the proxy is not added to the infrastructure. There can be different reason, but the most common case occour when you have proxyes that are “workgroup only” and when you are using dedicated local accounts, and not the “Administrator” one. And you have Windows Server 2012 or later.

Reading Time: 5 minutesUila has a very interesting product that provide a holistic full stack monitoring and visualization of an entire infrastructure from the hardware to the applications and services, end-to-end. Uila provides a non-disruptive and scalable application auto-discovery solution for over 3000 applications and protocols with Deep Packet Inspection (DPI) technology and automatically correlates any application performance issues with underlying network, storage and compute performance to get to root-cause.

Reading Time: 5 minutesLinux Kernel 4.15 è stato rilasciato il 28 gennaio 2018, dopo un lungo ciclo di sviluppo, tanto da arrivare alla RC9, cosa che non succedeva dal 2011. Questa versione è la prima che contiene specifiche ottimizzazioni e soluzioni specifiche per Meltdown e Spectre issues (benché anche alcuni kernel precedenti avessero alcune protezioni). Notare che in realtà i problemi sono tre problemi distinti: Meltdown è uno, ma poi ci sono due varianti di Spectre (note come v1 e v2). Il Kernel 4.15 al momento manca ancora mancano ancora dei fix per ARM e per la variante 1 […]

Reading Time: 3 minutesRubrik ha annunciato l’acquisizione di Datos IO, importante azienda nel backup e recovery di database NoSQL e di file system di big data. Datos IO offre un approccio radicalmente innovativo alla gestione dei dati, aiutando le organizzazioni ad adottare il cloud in tutta sicurezza offrendo soluzioni che proteggono, mobilitano e monetizzano i propri dati, su vasta scala. L’acquisizione di Datos IO amplierà la presenza di Rubrik su database e applicazioni cloud mission-critical, sempre più spesso adottati dai team applicativi e DevOps di aziende di livello Fortune 500.